Walk-In
Rooms

Associated
Environmental Systems offers a range of prefabricated, tight-tolerance
environmental walk-in rooms that are easy to ship and install. Major
features include:
- Forced
air circulation systems distribute air evenly and
constantly recirculate it, maintaining uniform and accurate
temperatures and humidity.
- Temperature Ranges are
from -73°C (-100°F) to +85°C.
- Refrigeration
system
meets the room's load demand and operates continuously in cooling mode.
Single-stage mechanical units operate at -35°C and above and two-stage
cascade units at below -35°C.
- Electric
heating system provides very accurate and
straight line control of temperatures. System is reliable and has a
long life.
- Humidity
System
choices are the conditioned fine Mist System or the Steam Generator
System. Different ranges are available including special dehumidity
ranges to 5% RH.
- Prefabricated room
construction consists of modular, sandwich-type panels with
a metal skin inside and outside. Panels are easy to ship and assemble.
- Multipane
viewing windows can be ordered in custom sizes.
- Incandescent
or fluorescent lighting is vapor-proofed and
sealed.
- Instrumentation
consists of single or two-channel microprocessor
programmers with an
accuracy of ±.25°C or better at the sensor. Other options include:
RS-232C, RS-422A, IEEE-488 interface.
- Safety
standard is a redundant control circuit with its
own controller and failsafe contactor. Many other options are
available.

Refrigeration
Systems
AES supplies a refrigeration package that supports the load demands of
the Walk-In Environmental Room.
- Single-stage mechanical
refrigeration systems operate at -35°C and above.
- Two-stage cascade refrigeration
systems (air cooled or water cooled) operate below -73°C.
All Walk-in Room
Systems:
- Operate continuously in cooling
mode.
- Provide a hot gas by-pass system
to automate capacity reduction when the room is at the set point
temperature.
- Are
constructed with high quality components including: liquid line
solenoids, liquid sight glass, dryers, strainers, and TX valves.
- Contain Copeland semihermetic (or
equal) compressors.
- Contain Penn (or equal) controls.
- Comply with ASHRAE guidelines for
piping and rating.
- Are factory-assembled and tested.
- Are simple to maintain because
components are easily accessible and clearly labeled.
Up to 5 HP units can be mounted on
the roof of the walk-in room. Larger units are installed on the floor
next to the room.
Comprehensive piping diagrams,
schematics, and charging data are available for our environmental
walk-in rooms.

Walk-in
Room Construction
Rooms
are constructed of prefabricated metal tongue and groove sectional
panels. An assembled room has continuous steel perimeters to hold
panels tightly in place.
Panel features include:
- 100% insulation
- Light weight for easy handling –
average weight of the largest panel is 84 lbs.
- Alignment pins for accurate fit.
- Steel straps connect locking arms
with locking pins on opposite sides of panels.
- Cam-actuated locks ensure tight
fits and accommodate frequent assembly/disassembly for relocating or
enlarging the room.
Viewing
Windows
The standard multipane window has a 14" by 23" viewing area.
Thermostatically controlled heater wire in the window casing minimizes
condensation and frost formation on the window surface. Custom size
windows are available.
Lighting
All lighting fixtures are vapor proof and sealed. Both
incandescent and flurorescent lighting fixtures are available.
Incandescent lighting is recommended for high temperature units
operating above +110°F and low temperature units operating below 0°F.
Forced
Air Circulation Systems
All walk-in rooms incorporate forced air circulation. Differences in
the size of the test chamber and its internal configuration are
accommodated by various airflow patterns, including horizontal,
vertical, or a combination of both. These provide an even distribution
of air and tight temperature control. Noise is also a consideration.
The
air circulation systems use external heavy duty motors to distribute
air evenly and constantly recirculate it, maintaining uniform and
accurate temperatures and humidity. The high quality motors have
internal cooling fans, protectors, and stainless steel shafts. Aluminum
or stainless steel squirrel cage blowers circulate the air. All mixing
is within a plenum that is external to the walk-in room work area.
In
tight tolerance environmental walk-in rooms, air must be evenly
distributed and constantly recirculated at a higher than normal rate in
order to maintain uniformity and accuracy. A portion of one wall of the
room is devoted to a conditioning plenum. Air is drawn into the lower
part of the plenum through a set of cleanable filters, across an
evaporator coil and vertically across electric heaters. The air then
enters centrifugal fans and is discharged into a perforated ceiling
plenum. The air flows vertically downward in the room and is returned
horizontally through the cleanable filters to the wall plenum.
Electric
Heating System
The combination of airflow, instrument response, and fast-reacting
heaters provides very accurate and straight line control of
temperatures.
Air
is passed over the fast response, low watt density heaters with ceramic
cores. This type of system provides very accurate air and humidity
control. A separate instrument precisely controls the heat level.
The heating systems have a long life
and are very reliable, with no down time.
Instrumentation
Instrumentation
consists of either single or two-channel microprocessor programmers
with an accuracy of ±.25°C or better at the sensor. The sensors are
fast acting 100 Ohm. platinum type.
Other options include: RS-232,
IEEE-488 interface.
Safety
Standard is a redundant control circuit with its own controller and
failsafe contactor. To prevent thermal runaway, the safety control
shuts off power to the heater circuit and the circulation blowers
continue to distriibute heat within the room. This feature is
particularly important if there are heat-generating items in the
walk-in room. When the temperature goes down, the safety control closes
and power is restored to the heaters.
Other
available safety options are: High Temperature Safety with Complete
Shut Down of Room with Manual Reset and Visual Indication, Low
Temperature Safety with Complete Shut Down of Room with Manual Reset
and Visual Indication, Both High and Low Temperature Safety with Manual
Reset on Both and Visual Indication, Audible Alarm, and Remote Station
Alarms.
Electrical Requirements
Standard
power requirements include 208V 3PH 60HZ, 220/240V 3PH 60HZ, 460V 3PH
60HZ, 208/220V 1PH 60HZ. Other power requirements are available upon
request.
Temperature Ranges
Various
ranges can be provided, including fast change rates with your product
load. Ranges from -73°C (-100°F) to +85°C are available.

Humidity
Standard
ranges available are: 20% to 95% ±5% RH. 10% to 98% ±2% RH. Different
ranges available including special dehumidity ranges to 5% RH.
Humidity
System
Two Humidity systems are standard:
- Fine Mist System is recommended
when doing continuous testing with high live loads.
- Steam
Generator System is recommended for rooms being used for low and high
humidity testing within the
System range of +40°F to +130°F.
The
conditioned Fine Mist System uses your local water supply. Steam is
created within a plenum outside the room area by spraying a fine mist
over a stainless steel sheath-type heater. The circulation system
carries this steam throughout the walk-in room.
The
Steam Generator System uses an external self-contained steam generator
with all necessary safety and water level controls to provide
humidities to saturation point within the walk-in room.
Download
Brochure:

|