| Model |
Working
Volume |
Dimensions
H x W x D |
Temperature
Range |
Rise
Time |
Pull Down
Time |
Humidity
Range |
Power
Requirements |
Download
Brochure |
| BHD-403 |
3 Cubic Ft. |
Internal
16" x 20" x 18"
External
28" x 49" x 28" |
-17°C to +177°C
-0°F to +350°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 25 minutes |
20% to 98%
±2% RH
limited by +2°C dew point |
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz. |
 |
| BHD-405 |
5 Cubic Ft. |
Internal
20" x 20" x 22"
External
32" x 49" x 32" |
-17°C to +177°C
-0°F to +350°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 25 minutes |
20% to 98%
±2% RH
limited by +2°C dew point |
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz. |
 |
| BHD-408 |
8 Cubic Ft. |
Internal
24" x 24" x 24"
External
34" x 53" x 34" |
-17°C to +177°C
-0°F to +350°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 25 minutes |
20% to 98%
±2% RH
limited by +2°C dew point |
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz. |
 |
| BHD-503 |
3 Cubic Ft. |
Internal
16" x 20" x 18"
External
28" x 49" x 28" |
-37°C to +177°C
-35°F to +350°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 35 minutes |
20% to 98%
±2% RH
limited by +2°C dew point |
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz. |
 |
| BHD-505 |
5 Cubic Ft. |
Internal
20" x 20" x 22"
External
32" x 49" x 32" |
-37°C to +177°C
-35°F to +350°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 35 minutes |
20% to 98%
±2% RH
limited by +2°C dew point |
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz. |
 |
| BHD-508 |
8 Cubic Ft. |
Internal
24" x 24" x 24"
External
34" x 53" x 34" |
-37°C to +177°C
-35°F to +350°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 35 minutes |
20% to 98%
±2% RH
limited by +2°C dew point |
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz. |
 |
| BHD-203 |
3 Cubic Ft. |
Internal
16" x 20" x 18"
External
28" x 49" x 28" |
-65°C to +177°C
-85°F to +350°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 70 minutes |
20% to 98%
±2% RH
limited by +2°C dew point |
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz. |
 |
| BHD-205 |
5 Cubic Ft. |
Internal
20" x 20" x 22"
External
32" x 49" x 32" |
-65°C to +177°C
-85°F to +350°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 70 minutes |
20% to 98%
±2% RH
limited by +2°C dew point |
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz. |
 |
| BHD-208 |
8 Cubic Ft. |
Internal
24" x 24" x 24"
External
34" x 53" x 34" |
-65°C to +177°C
-85°F to +350°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 70 minutes |
20% to 98%
±2% RH
limited by +2°C dew point |
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz. |
 |